After power is applied, the display fails to light up and the device does not function.

If the LOCR switch is faulty, simply replace it.

Instrument A/M is out of order.

Replace the instrument panel cover (after checking the instruments, they function normally).

The instrument parameter keeps jumping to 1818.

Thermocouple is faulty.

The instrument does not display.

Replace the power board.

There is a problem with the instrument parameters.

The thermocouple wires were connected in reverse; after correcting the wiring, the instrument parameters are now correct.

Instrument panel buttons are not functioning.

Watch movement returned for inspection

Before the equipment starts, the PV value is incorrect and displays 0; it should normally show the room temperature.

If the initial PV reading displays “0” or “4,” the temperature control instrument is suspected to be faulty; please return the faulty meter core for inspection.

The left button on the instrument panel is not functioning.

The instrument parameter LOC has been modified; after restoring it, the buttons function normally.

After the equipment is started, there is a continuous hissing sound, and the instrument panel keeps flashing.

The noise from the fan blade contacting the wire has been resolved by securing the wire bundle.

After the LOCR switch is turned on, the instrument panel light does not illuminate.

Fuse damaged

The equipment’s display has consistently shown “stop,” and I cannot access the settings menu, nor can I start the program.

The instrument has been returned for re-inspection.

The PV window on the instrument displays “1312”; the SV window displays “orRL”.

Thermocouple failure: open circuit or connection at the wiring terminal has come loose.

When the BTF-1400 program is running, the PV display shows that the temperature is not rising.

Heating rod disconnected / Green operation button not pressed