Why has the tube furnace suddenly become so loud?

This issue is caused by the aging of the main contacts of the electrical contactor in the 2015‑year‑old equipment, resulting in poor contact. Pressing “turn-off” once and then pressing “turn-on” again can resolve the problem.

Abnormal noise from the equipment

Clean the dust from the device’s fan.

The stove makes an unusual noise when turned on.

Fan damaged; replace the fan.

After powering on the PECVD system, the equipment does not operate and emits a squeaking sound.

1. When the matcher’s ground is connected in parallel with the RF cable, 2. when the matcher’s ground is wired separately from the RF cable, the equipment operates normally.

Unusual noise from the stove

The AC contactor (NC6-09/0910/AC 220 V, 50 Hz) has one unit with poor contact.