MF-1200C-L/ Large chamber muffle furnace
Main Features
Heat insulating materials adopt Alumina fiber inorganic ones, which is formed with vacuum absorption, environmental protecting and energy saving.
Furnace body is double air cooling structure to control furnace surface Temp. no more than 60℃ when furnace is heated into max. Temp.
Made of various heat insulating materials to make furnace energy consumption less(electric consumption is only 25% of the same type furnace consumption)
Technical Parameters
|
|
||||||||
Power |
Power rated: 6KW (208-240V) |
||||||||
Voltage |
Voltage rated: AC 208-240V 50/60HZ |
||||||||
Furnace Construction
|
High purity fibrous alumina insulation for maximum energy saving - 30% less power consumption than other brands Double air cooling structure to control furnace surface Temp. no more than 60℃ when furnace is heated into max. Temp.
The spring door buckle is used to solve the contraction gap caused by high temperature in the chamber of the equipment.
|
||||||||
Working Temperature
|
Max. Temperature: 1200℃ Continuous working temperature: ≤1100℃ |
||||||||
Max. heating rate |
10℃/min |
||||||||
|
PID automatic control and auto-tune function. 30 programmable segments for precise thermal processing. Built-in protection for the over-heated and broken thermocouple. |
||||||||
Thermocouple |
K type |
||||||||
Heating Elements |
Fe-Cr-Al Alloy doped by Mo |
||||||||
Temperature Accuracy |
+/- 1℃ |
||||||||
Dimensions
|
Chamber size(L*D*H): 400*400*400mm (64L) Furnace size(L*W*H): 650*620*940mm |
||||||||
Net Weight |
115kg |
||||||||
Packing dimensions(L*W*H) |
690*660*1000mm(wooden case) |
||||||||
Shipping weight |
170kg |
||||||||
Warranty |
1 year limited warranty with lifetime support (Such consumable parts as resistance wire are NOT supported by the warranty) |
||||||||
Attention |
The equipment is not sealed, and can not be put into toxic, harmful, inflammable and explosive gas. Can add the inlet port to pass through the inert gas or oxygen.
Small cracks may appear on the surface of the refractory ceramics over extended use. This is a normal occurrence and the cracks may be repaired with alumina coating. You shall place the sample in to a crucible. Never place sample on the chamber bottom directly. |
||||||||
Compliance |
CE Certified |
||||||||
|
|