Roll-to-Roll Continuous CVD Growth Equipment RTR-III-80

Equipment Model: RTR-III-80 Equipment Overview: This equipment, developed by our company, is a specialized continuous‑growth system designed for the production of graphene films or linear materials. It is a rapid‑cooling, roll‑to‑roll CVD continuous growth furnace, comprising a high‑temperature growth chamber, a three‑channel mass‑flow‑meter gas delivery system, a vacuum pumping unit, quartz tubes, a cooling assembly, sealed take‑up and pay‑off mechanisms, and an automated control system. At each end, there are dedicated feed‑in/air‑intake vacuum chambers and discharge‑out/ventilation vacuum chambers—these serve as sealed enclosures for handling copper foil or fiber filaments. Inside the take‑up and pay‑off sealing units, unwind and rewind rollers are installed, respectively. A cooling device is mounted between the exhaust chamber and the furnace body. Compared with existing technologies, this system offers rapid cooling and continuous growth, enabling large‑area, high‑quality graphene production or the continuous synthesis of linear materials. (For fiber‑growth processes, a fiber tension meter is included; by adjusting motor speed, continuous fiber feeding and uniform tension can be achieved.)

Keywords:

Close
  • 产品对比
Total X Clear all
  • Product Information
  • Product Video
  • Experimental Case
  • Accessories and Consumables
  • Heating system

    ·   Voltage: Single-phase 220V 50Hz

    ·   Maximum temperature: 1200℃

    · Use Temperature: ≤1100℃

    · Furnace lining materials: alumina, high-temperature fiber products

    · Furnace chamber effective dimensions: Φ80 mm (suitable for 2–3-inch samples; the furnace tube diameter can be customized to meet specific requirements)

    ·   Heating zone length: 200+200+200 mm

    · Temperature control method: 30 programmable temperature‑control segments, with auto‑tuning of PID parameters; the operator interface is a 7‑inch industrial PC, featuring a built-in PLC control program.

    · Temperature control accuracy: ±1℃

    · Heating element: resistance wire

    · Thermocouple type: Type K

    Three-way proton flux control system

    · Connector Type: Double Ferrule Stainless Steel Connector

    · Standard range (N 2 ): 200 sccm, 500 sccm, 1000 sccm (customizable according to user requirements)

    · Accuracy: ±1.5% F.S.

    · Linearity: ±1% F.S.

    · Repeatability: ±0.2% F.S.

    · Response time: Gas characteristics   1–4 seconds, electrical characteristics  10Sec

    · Working pressure differential range: 0.1–0.5 MPa

    · Maximum pressure: 3 MPa

    · Interface: Φ6, 1/4''

    · Display: 4-digit display

    · Operating ambient temperature: 5–45°C, high-purity gas

    · Pressure vacuum gauge: −0.1 to 0.15 MPa, 0.01 MPa per division

    · Gate valve: Φ6

    · Double-sided polished stainless steel pipe: Φ6

    Low-vacuum unit

    · Operating voltage: 220V ±10%, 50–60 Hz; Power: 1 kW

    · Operating ambient temperature: 5~ 40℃

    · Relative air humidity: ≤85%

    · Pumping speed: 10 m³/h

    · Ultimate vacuum level: 5 x 10 -1 Pa

    · Working pressure range: 1.01325 x 10 5  ~   1.33 x 10 -2 Pa

    · Withstand voltage: 0.03 MPa

    · Oil capacity: 1.1 L

    · Inlet/Outlet Port Diameter: KF25

    · Noise: 50 dB

    · Connection method: A bellows is used, and the manual damper valve is connected to the bellows.

    Warranty period

    ·   One-year warranty, lifetime maintenance.

    · Consumable parts such as thermocouples, sealing rings, and furnace tubes are not included.

    · Damage caused by human error or by the use of corrosive and acidic gases is not covered under warranty.

    Precautions

    · The gas pressure inside the furnace tube shall not exceed 0.02 MPa (gauge pressure).

    ·   For experiments involving sample heating, it is not recommended to operate the system with both the vacuum valve and the inlet valve at the furnace tube flange closed. If it becomes necessary to close these valves during heating, closely monitor the pressure gauge; if the pressure exceeds 0.02 MPa, immediately open the vent valve to prevent potential accidents, such as rupture of the furnace tube or ejection of the flange.

    ·   If, due to process requirements, flammable, explosive, or toxic gases must be used, you are responsible for implementing all necessary safety and explosion‑proof measures. Our company shall not be liable for any issues arising from improper operation during the use of such gases.

    · As usage time increases, small cracks may appear on the furnace lining; this is normal, and the cracks can be repaired with an alumina coating.