Front-Opening Vacuum Well-Type Crucible Furnace BTF-1200C-VF-B

Equipment Model: BTF-1200C-VF-B Equipment Overview: The BTF-1200C-VF-B is a CE‑certified vacuum well‑type crucible furnace that integrates the control system and the furnace chamber into a single unit. Its furnace chamber employs all‑in‑one vacuum‑adsorption forming for thermal insulation, with imported resistance wires embedded in a programmable control system. Featuring an extra‑large quartz furnace cavity and a vacuum‑sealed flange system, it enables rapid sample heating under both flowing atmospheres and vacuum conditions, serving as an excellent replacement for conventional vacuum box furnaces. The furnace’s control panel is equipped with an intelligent temperature controller, along with controls for the power switch, main heating start/stop buttons, and operational status indicator lights, allowing real-time monitoring of the system’s operating condition. Process Applications: This equipment is specially designed for universities, research institutes, and industrial and mining enterprises to perform rapid sintering, melting, and analysis of metallic, nonmetallic, and other chemical materials under controlled atmospheres or in a vacuum environment.

Keywords:

Close
  • 产品对比
Total X Clear all
  • Product Information
  • Product Video
  • Experimental Case
  • Accessories and Consumables
  • Key Features

    ·   Integrates the control system with the furnace chamber.

    ·   The furnace lining insulation material is manufactured via an integral vacuum‑adsorption molding process, with imported resistance wires embedded under computer control.

    ·   The large-diameter quartz furnace chamber and vacuum-sealed flange system enable rapid sample heating under both flowing atmospheres and vacuum conditions.

    Main Parameters

    · Rated voltage: AC 208-240V Single Phase, 50/60 Hz

    ·   Heating power: 4 kW

    · Maximum temperature: 1200℃

    ·   Operating temperature: ≤1100℃

    · Maximum heating rate: 40°C/min

    · Heating element: resistance wire

    · Thermocouple: Type K thermocouple

    · Furnace door structure: front-opening type

    Furnace tube &Flange

    ·   Furnace tube diameter: High-purity quartz inner liner Φ210×340mm

    ·   Stainless steel sealing flange

    Temperature control system

    ·   Fuzzy PID Control and Self-Tuning Regulation

    ·   Intelligent 30-segment programmable control allows customers to customize heating and cooling profiles according to their specific requirements.

    ·   Features ultra‑gentle operation and open‑circuit alarm functionality.

    · Temperature control accuracy: ±1℃

    Vacuum System (Optional)

    ·   Model: DRV-10

    · Pumping rate: 10 m³/h

    · Ultimate pressure: 5×10 -1 Pa (no-load, cold state)

    · Oil capacity: 1.1 L

    · Inlet/Outlet Port Diameter: KF25

    (Optional: domestically produced or imported high-vacuum unit)

      

    Size &Weight

    · Device dimensions: 510*435*425mm (Length*Width*Height)

    · Equipment net weight: approximately 70 kg

    Warranty period

    ·   One-year warranty, lifetime maintenance.

    · Consumable items such as thermocouples, silicone rings, quartz tubes, and sample crucibles are not included.

    · Damage caused by human misuse or by the use of corrosive and acidic gases is not covered under warranty.

    Precautions

    ·   The gas pressure inside the quartz tube must not exceed 0.02 MPa (gauge pressure).

    ·   Due to the high internal pressure of the gas cylinder, a pressure-reducing valve must be installed when introducing gas into the quartz tube. To ensure safety, it is recommended to use a pressure-reducing valve with a rated pressure below 0.02 MPa and a measurement range of 0.01–0.1 MPa, which will provide greater accuracy and safety during operation.

    ·   For experiments involving sample heating, it is not recommended to operate the system with both the vacuum valve and the inlet valve at the furnace tube flange closed. If it becomes necessary to close these valves during sample heating, continuously monitor the pressure gauge; if the pressure exceeds 0.02 MPa, immediately open the vent valve to prevent potential accidents, such as rupture of the furnace tube or ejection of the flange.

    ·   Customers are advised against using flammable, explosive, or toxic gases. If such gases are unavoidably required for process reasons, please implement all necessary safety and explosion‑proof measures on your own. Our company shall not be held liable for any issues arising from the use of flammable, explosive, or toxic gases.

Consultation Message