undefined
+
  • undefined

1200℃ Intelligent Single-Zone Sliding-Rail Heat Treatment Equipment BTF-1200C-SL-4Z

Equipment Model: BTF-1200C-SL-4Z Equipment Overview: The tubular vacuum/atmosphere purification and separation system is primarily used to perform inert-gas purging after preliminary evacuation under vacuum conditions. Under atmospheric-pressure‑maintaining flow (one inlet and one outlet), it enables sublimation of organic mixtures for purification—i.e., evaporation followed by recrystallization. Its main applications include processing organic materials with sublimation properties or mixtures exhibiting mobile-phase retention, such as organic optoelectronic products (organic photoelectric materials used in organic light‑emitting displays) and nanomaterials.

Keywords:

Close
  • 产品对比
Total X Clear all
  • Product Information
  • Product Video
  • Experimental Case
  • Accessories and Consumables
  • Main Parameters

    · Voltage: Single-phase 220V, 50Hz; Rated power: 3kW

    ·   Maximum temperature: 1200℃

    ·   Operating temperature: ≤1100℃

    ·   Heating zone length: 440 mm, Constant-temperature zone length: 200 mm

    · Heating element: resistance wire

    · Thermocouple Type: Type K Thermocouple

    Heating furnace chamber

    · Materials: Alumina, high-temperature fiber products

    · Structure: Can be opened in half

    · Sliding mechanism: The bottom of the heating furnace is fitted with guide rails, allowing manual adjustment of the sliding motion.

    Furnace tube &Flange

    ·   Furnace tube specifications: High-purity quartz tube, Φ100 × 1000 mm

    ·   Sealed flange: The right side features a water-cooled flange; the connection beneath the flange has been redesigned to eliminate the previous screw‑fastening method, making disassembly easier.

    Temperature control system

    · 30 programmable temperature control segments, with self-tuning PID parameters.

    ·   The operator interface is a 10-inch industrial PC with a built-in PLC control program.

    ·   The temperature control system can be set to programmatic control.

    · Temperature control accuracy: ±1℃

    Four-channel proton flux control system

    · Connector Type: Double Ferrule Stainless Steel Connector

    · Standard range (N 2 ): Methane 200 sccm, argon 200 sccm, argon 1000 sccm, hydrogen 500 sccm

    · Accuracy: ±1.5%

    · Linearity: ±0.5–1.5%

    · Repeatability: ±0.2%

    · Response time: Gas characteristics: 1–4 sec, Electrical characteristics: 10 sec

    · Working pressure differential range: 0.1–0.5 MPa

    · Maximum pressure: 3 MPa

    · Interface: Φ6, 1/4''

    · Display: 4-digit display

    · Operating ambient temperature: 5–45°C, high-purity gas

    · Pressure vacuum gauge: −0.1 to 0.15 MPa, 0.01 MPa/division

    · Gate valve: Φ6

    · Double-sided polished stainless steel pipe: Φ6

    Water chiller

    · Operating voltage AC 208-240V 50Hz

    · Operating current: 1.4–2.1 A

    · Compressor power: 0.295 kW

    · Cooling capacity: 2361 BTU/h

    · Water tank capacity: 6L

    · Maximum flow rate: 10 L/min

    · Safety Protection: Compressor overcurrent protection, flow alarm, and overtemperature alarm.

    · Weight: 26 kg

    · Mechanical dimensions: 55   x  28  x  43cm

    Warranty period

    ·   One-year warranty, lifetime maintenance.

    · Consumable parts such as thermocouples, sealing rings, and quartz tubes are not included.

    · Damage caused by human factors or by the use of corrosive and acidic gases is not covered under warranty.

    Precautions

    ·   The gas pressure inside the quartz tube must not exceed 0.02 MPa (gauge pressure).

    ·   Due to the high internal pressure of the gas cylinder, a pressure-reducing valve must be installed when introducing gas into the quartz tube. To ensure safety, it is recommended to use a pressure-reducing valve with a rated pressure below 0.02 MPa.

    ·   For experiments involving sample heating, it is not recommended to operate the system with both the vacuum valve and the inlet valve at the furnace tube flange closed. If it becomes necessary to close these valves during heating, closely monitor the pressure gauge; if the pressure exceeds 0.02 MPa, immediately open the vent valve to prevent potential accidents, such as rupture of the furnace tube or ejection of the flange.

    ·   Customers are advised against using flammable, explosive, or toxic gases. If such gases are unavoidably required for process reasons, please implement all necessary safety and explosion‑proof measures on your own. Our company shall not be liable for any issues arising from the use of flammable, explosive, or toxic gases.

Consultation Message