Construction Description
· Main CVD Equipment: The main CVD equipment primarily comprises a heating system, a gas delivery system, a vacuum system, and a furnace tube rotation mechanism.
① Heating System: A three-zone heating furnace with zone lengths of 300 mm + 300 mm + 300 mm, and a total heating power of 12 kW. Temperature control is achieved using K-type thermocouples, with one upper and one lower temperature‑control point in each zone, enabling independent temperature regulation and enhancing the uniformity of the furnace’s temperature field.
② Gas delivery system: six gas lines, each supplied by five D07-19B 500 sccm N 2 and 1 CS200A 500 sccm N 2 The mass flow meter controls the gas flow into the mixing tank. Additionally, a purge gas line is configured, with a D07-19B 5 slm N2 mass flow meter connected in parallel upstream of the mixing tank, enabling purging of the entire gas delivery system.
③ Vacuum System: Equipped with a BSV30 vacuum pump and a PCG550 vacuum gauge for monitoring the chamber’s vacuum level.
④ Furnace tube rotation mechanism: Equipped with a servo motor and a 1:30 reduction gear to ensure smooth rotation of the furnace tube.
· Feeding mechanism: Composed of a screw feeder, a lifting mechanism, and a sliding rail. Before feeding, the height of the screw feeder’s feed screw can be adjusted by manually turning the turbine‑driven lift handle; once aligned with the equipment flange’s center height, lock the upper guide post using its locking handle. The feed screw can then be moved left or right to the optimal position for material delivery.
· Material collection mechanism: A vacuum pump is used to create a vacuum inside the collection hopper. The collection rod is inserted into the material chamber within the equipment, and the ball valve on the collection rod is opened. The suction generated by the vacuum negative pressure draws the material into the collection hopper.
Key Features
· Three-section resistance‑wire heating furnace, with heating zones of 300 × 300 × 300 mm; independent temperature control at six upper and lower points; excellent temperature‑field uniformity.
· Both ends of the equipment are fitted with magnetorheological fluid‑sealed flanges, ensuring that the furnace tube can rotate under vacuum conditions.
· The equipment is equipped with a screw feeding mechanism, and the feed motor’s speed is adjustable, allowing for free regulation of the feeding rate.
· Integrated intelligent industrial control screen with display and control; the user interface is simple and easy to use.
Main Parameters
· Rated Voltage: AC 380 V 50/60 Hz
· Rated power: 15 kW (12 kW for heating + 1.5 kW for the vacuum pump + 1.5 kW for the motor)
· Maximum temperature: 1200℃
· Continuous Operating temperature: ≤1100℃
· Recommended heating rate: ≤10°C/min
· Heating zone dimensions: 300+300+300 mm; constant-temperature zone length: 600 mm.
· Furnace tube specification: Special-shaped quartz tube
· Heating element: resistance wire
· Thermocouple Type: Type K Thermocouple
Temperature control system
· 10-inch touchscreen control
· Fuzzy PID Control and Self-Tuning Regulation
· Intelligent 30-segment programmable control
· Features ultra‑gentle operation and open‑circuit alarm functionality.
· Temperature control accuracy: ±1℃
Size &Weight
· Main dimensions: 2600 x 960 x 1500mm
· Feeding mechanism: 1 600 x 600 x 1500mm
· Equipment net weight: approximately 600 kg
Warranty period
· One-year warranty, lifetime maintenance.
· Consumable parts such as thermocouples, sealing rings, and furnace tubes are not included.
· Damage caused by human error or by the use of corrosive and acidic gases is not covered under warranty.
Precautions
· The gas pressure inside the quartz tube must not exceed 0.02 MPa (gauge pressure).
· For experiments involving sample heating, it is not recommended to operate the system with both the vacuum valve and the purge valve at the furnace tube flange closed. If it becomes necessary to close these valves during heating, closely monitor the pressure gauge; if the pressure exceeds 0.02 MPa, immediately open the vent valve to prevent potential accidents, such as rupture of the furnace tube or ejection of the flange.
· If, due to process requirements, flammable, explosive, or toxic gases must be used, you are responsible for implementing all necessary safety and explosion‑proof measures. Our company shall not be liable for any issues arising from improper operation during the use of such gases.
· As the furnace is used over time, minor cracks may develop; this is normal, and the cracks can be repaired with an alumina coating.
-






Consultation Message
Contact Us
Service Hotline:400-0033-603
Sales Hotline:180 1997 0653,180 1997 3217,133 0551 1955
Sales Hotline:0551-65146333
After-sales hotline:0551-65148123
Sales email:besteq@163.com
Company Address: No. 6, Yixiu Road, Feixi County, Hefei City, Anhui Province
Anhui Beiyike Equipment Technology Co., Ltd.
Follow the official account
Research Equipment Consultation
Hubei, Jilin, Shaanxi, Heilongjiang
Tianjin, Liaoning, Henan, Hebei
Shanghai, Sichuan, Chongqing, Inner Mongolia
Xinjiang, Ningxia, Tibet, Qinghai
Foreign Trade Consulting
Sublimation Instrument Consultation
Industrial Equipment Consulting
Jiangsu, Zhejiang, Guangdong, Fujian
Hunan Shanxi Gansu Hainan
Guangxi
Beijing, Tianjin, Liaoning, Henan
Hebei, Shanghai, Sichuan, Chongqing
Inner Mongolia, Xinjiang, Ningxia
Tibet Qinghai
Anhui, Guizhou, Yunnan, Hubei
Jilin, Shaanxi, Heilongjiang, Jiangxi
Shandong
Foreign Trade Consulting
Sublimation Instrument Consultation
Process Consulting
After-sales consultation
Copyright © 2026 Anhui Beiyike Equipment Technology Co., Ltd. All rights reserved.