1200℃ Four-Channel Integrated Tube Furnace BTF-1200C-S-4D

Equipment Model: BTF-1200C-S-4D Equipment Overview: The BTF-1200C-S-4D is a four-channel integrated tube furnace. It consists of an upper open‑type tube section, a centrally enclosed tube furnace, and an intelligent industrial control operating system.

Keywords:

Close
  • 产品对比
Total X Clear all
  • Product Information
  • Product Video
  • Experimental Case
  • Accessories and Consumables
  • Furnace structure

    · Open‑type and closed‑type tube furnaces: The single‑zone heating furnace employs lightweight alumina fiber insulation, with K‑type thermocouples for temperature measurement and high‑quality resistance wire as the heating element, ensuring a uniform internal temperature profile and long service life.

    ·   Intelligent industrial control operating system: features intelligent PID‑fuzzy control, 30‑segment programmable temperature regulation with a temperature accuracy of ±1°C, and includes thermocouple‑break detection, over‑temperature protection, and alarm functions. It provides paperless recording of operational process data and can connect to a computer for one‑click data export.

    Main Parameters

    ·   Rated voltage: AC 380V, 50/60 Hz

    ·   Total heating power: ≤10 KW

    · Maximum temperature: 1200℃

    · Continuous Operating temperature: ≤1100℃

    · Heating rate: 10°C/min

    · Heating zone length: 230 mm

    · Heating element: resistance wire

    · Thermocouple type: Type K

    Temperature control system

    ·   Fuzzy PID Control and Self-Tuning Regulation

    · AI-enabled 30-segment programmable control

    ·   Features ultra‑gentle operation and open‑circuit alarm functionality.

    · Temperature control accuracy: ±1℃

    Size &Weight

    · Main unit dimensions: 800 x 450 x 1350 mm (L x W x H)

    · Equipment net weight: approximately 150 kg

    Warranty period

    ·   One-year warranty, lifetime maintenance.

    · Consumable items such as thermocouples, silicone rings, furnace tubes, and sample crucibles are not included.

    · Damage caused by improper use or by the use of corrosive and acidic gases is not covered under warranty.

    Precautions

    ·   The gas pressure inside the quartz tube must not exceed 0.02 MPa (gauge pressure).

    ·   Due to the high internal pressure of the gas cylinder, a pressure-reducing valve must be installed when introducing gas into the quartz tube. To ensure safety, it is recommended to use a pressure-reducing valve with a rated pressure below 0.02 MPa and a measurement range of 0.01–0.1 MPa, which will provide greater accuracy and safety during operation.

    ·   For experiments involving sample heating, it is not recommended to operate the system with both the vacuum valve and the purge valve at the furnace tube flange closed. If it becomes necessary to close these valves during heating, closely monitor the pressure gauge; if the pressure exceeds 0.02 MPa, immediately open the vent valve to prevent potential accidents, such as rupture of the furnace tube or ejection of the flange.

    ·   Customers are advised against using flammable, explosive, or toxic gases. If such gases are unavoidably required for process reasons, please implement all necessary safety and explosion‑proof measures on your own. Our company shall not be held liable for any issues arising from the use of flammable, explosive, or toxic gases.