1200℃ three-zone tubular CVD system BTF-1200C-III-3ZL-CVD

Equipment Model: BTF-1200C-III-3ZL-CVD Equipment Composition: This equipment primarily consists of a multi‑channel gas supply system, a three‑zone heating furnace, a low‑vacuum system, and an intelligent pressure‑control module.

Keywords:

Close
  • 产品对比
Total X Clear all
  • Product Information
  • Product Video
  • Experimental Case
  • Accessories and Consumables
  • Construction Description

    · Open-type furnace: The three-zone heating furnace is constructed with lightweight alumina fiber, employs K‑type thermocouples for temperature measurement, and utilizes high‑quality resistance wire as the heating element, ensuring a uniform internal temperature field.

    · Multi‑channel gas supply system: The mass flow meter can, according to programmed settings, deliver multiple gases either individually or in mixtures, offering convenient operation and precise control.

    · Intelligent pressure-control module: It uses a vacuum gauge to monitor the internal pipeline pressure in real time, and the PLC adjusts the valve opening degree according to the set pressure value, thereby maintaining stable internal pipeline pressure.

    · Low-vacuum system: equipped with an imported mechanical pump and an imported vacuum gauge, ensuring reliable performance.

    Main Parameters

    ·   Voltage: AC 220V, Total Heating Power: ≤8kW

    ·   Maximum temperature: 1200℃

    · Continuous Operating temperature: ≤1100℃

    · Heating rate: ≤10°C/min

    ·   Heating zone length: 300+300+300 mm

    · Heating element: resistance wire

    · Thermocouple type: Type K thermocouple

    Temperature control system

    ·   Fuzzy PID Control and Self-Tuning Regulation

    ·   AI-enabled 30-segment programmable control

    ·   Features ultra‑gentle operation and open‑circuit alarm functionality.

    · Temperature control accuracy: ±1℃

    Size &Weight

    · Equipment main body dimensions: 2000  x 700   x 1300mm (Length × Width × Height)

    · Equipment weight: approximately 150 kg

    Gas‑line system parameters (mass flow meters available in multiple channel configurations)

    · Reference flow range of the mass flow meter (N 2 ): 100 sccm, 200 sccm, 500 sccm, 1000 sccm (range selectable)

    · Accuracy: ±1.5%

    · Linearity: ±0.5–1.5%

    · Repeatability: ±0.2%

    · Response time: ≤10 sec

    · Working pressure differential range: 0.1–0.5 MPa

    · Maximum pressure: 3 MPa

    · Interface: Φ6, 1/4''

    · Display: 4-digit display

    · Operating ambient temperature: 5–45°C, high-purity gas

    · Pressure vacuum gauge: −0.1 to 0.15 MPa, 0.01 MPa/division

    · Gate valve: Φ6

    · Double-sided polished stainless steel pipe: Φ6

    · Connector Type: Double Ferrule Stainless Steel Connector

    Low-vacuum system parameters

    · Power supply: 220V, 50Hz; Motor power: 0.4 kW

    · Pumping speed: 10 m³/h

    · Ultimate vacuum level: 5x10 -1 Pa

    · Inlet/Outlet Connection: KF25

    · Oil capacity: 1.1 L

    · Motor speed: 1440 rpm

    · Operating ambient temperature: 5~ 40℃

    · Noise: ≤56dB

    Warranty period

    ·   One-year warranty, lifetime maintenance.

    · Consumable parts such as thermocouples, sealing rings, and quartz tubes are not included.

    · Damage caused by human error or by the use of corrosive and acidic gases is not covered under warranty.

    Precautions

    ·   The gas pressure inside the quartz tube must not exceed 0.02 MPa (gauge pressure).

    ·   Due to the high internal pressure of the gas cylinder, a pressure-reducing valve must be installed when introducing gas into the quartz tube. To ensure safety, it is recommended to use a pressure-reducing valve with a rated pressure below 0.02 MPa.

    ·   For experiments involving sample heating, it is not recommended to operate the system with both the vacuum valve and the inlet valve at the furnace tube flange closed. If it becomes necessary to close these valves during heating, closely monitor the pressure gauge; if the pressure exceeds 0.02 MPa, immediately open the vent valve to prevent potential accidents, such as rupture of the furnace tube or ejection of the flange.

    ·   Customers are advised against using flammable, explosive, or toxic gases. If such gases are unavoidably required for process reasons, please implement all necessary safety and explosion‑proof measures on your own. Our company shall not be held liable for any issues arising from the use of flammable, explosive, or toxic gases.

Consultation Message