1100℃ Vacuum Quenching Furnace BTF-1100C-H

Equipment Model: BTF-1100C-H Equipment Overview: This is a vacuum quenching furnace with an air inlet at the top and an air outlet at the bottom. The control cabinet is independently designed, and the equipment features a simple yet robust exterior, ensuring intuitive and convenient operation. Electrical control is managed by a built-in temperature controller that employs intelligent PID regulation and automatic tuning, supporting up to 30 programmable segments. Temperature control accuracy is ±1°C, with over‑temperature protection and thermocouple‑breakage alarm functions. The furnace chamber is constructed from alumina fiber, and K‑type thermocouples are used for temperature measurement, paired with high‑quality resistance heating elements to ensure uniform internal temperature distribution. Application Fields: Widely used in metallurgy, mechanical engineering, light industry, commodity inspection, higher education institutions, and research organizations.

Keywords:

Close
  • 产品对比
Total X Clear all
  • Product Information
  • Product Video
  • Experimental Case
  • Accessories and Consumables
  • Equipment Structure

    ·   Electrical Control: Equipped with a built-in temperature controller featuring intelligent PID control and automatic tuning, it supports up to 30 programmable segments. Temperature control accuracy is ±1°C, and it includes over-temperature and thermocouple‑open‑circuit alarm functions.

    ·   Heating furnace chamber: constructed from alumina fiber, equipped with K-type thermocouples for temperature measurement and high-quality resistance wire as the heating element, ensuring a uniform internal temperature field.

    Main Parameters

    · Rated voltage: AC 220V 50/60 Hz

    · Heating power: 2.5 kW

    · Maximum temperature: 1100℃

    · Continuous Operating temperature: ≤1000℃

    · Recommended heating rate : ≤10℃/min

    ·   Heating zone length: 330 mm

    · Heating element: resistance wire (molybdenum‑doped iron‑chromium‑aluminum alloy)

    · Thermocouple: Type K

    Furnace tube &Flange

    ·   High-purity quartz tube Φ50×600 mm

    ·   Standard configuration includes a stainless steel vacuum flange with a valve, sealed with a silicone O-ring.

    · Vacuum level: 0.5 Pa (using a mechanical pump)

    · It is equipped with a mechanical pressure gauge, with a measurement range of -0.1 to 0.15 MPa.

    ·   The tube plug blocks the thermal radiation emitted from the tube center and must be inserted into the correct position within the furnace before heating (quartz or alumina tube plugs are available as options).

    Temperature control system

    ·   Fuzzy PID Control and Self-Tuning Regulation

    ·   Intelligent 30-segment programmable control allows customers to customize heating and cooling profiles according to their specific requirements.

    ·   Features ultra‑gentle operation and open‑circuit alarm functionality.

    · Temperature control accuracy: ±1℃

    Vacuum pressure

    ·   The mechanical pump can reach 1 Pa.

    ·   The molecular pump can reach 10. -4 pa

    Size &Weight

    · Device dimensions: 360*350*1200mm (Length*Width*Height)

    · Equipment net weight: approximately 30 kg

    Warranty period

    ·   One-year warranty, lifetime maintenance.

    · Consumable items such as thermocouples, silicone rings, furnace tubes, and sample crucibles are not included.

    · Damage caused by improper use, as well as damage resulting from the use of corrosive or acidic gases, is not covered under the warranty.

    Precautions

    ·   The internal air pressure must not exceed 0.02 MPa (gauge pressure).

    ·   Due to the high internal pressure of the gas cylinder, a pressure-reducing valve must be installed when introducing gas into the pipeline. To ensure safety, it is recommended to use a pressure-reducing valve with a rated pressure below 0.02 MPa and a measurement range of 0.01–0.1 MPa, which will provide greater accuracy and safety during operation.

    ·   For experiments involving sample heating, it is not recommended to operate the system with both the vacuum valve and the purge valve at the furnace tube flange closed. If it becomes necessary to close these valves during heating, continuously monitor the pressure gauge; if the pressure exceeds 0.02 MPa, immediately open the vent valve to prevent potential accidents, such as rupture of the furnace tube or ejection of the flange.

    ·   Customers are advised against using flammable, explosive, or toxic gases. If such gases are unavoidably required for process reasons, please implement all necessary safety and explosion‑proof measures on your own. Our company shall not be held liable for any issues arising from the use of flammable, explosive, or toxic gases.