1200℃ Small Vertical Tube Furnace BTF-1200C-S-VT

Equipment Model: BTF-1200C-S-VT Equipment Overview: This equipment features a vertical frame design, with the heating furnace securely mounted on the frame. It is equipped with pushbuttons and instruments to facilitate experimental operation of the heating furnace.

Keywords:

Close
  • 产品对比
Total X Clear all
  • Product Information
  • Product Video
  • Experimental Case
  • Accessories and Consumables
  • Key Features

    ·   An atmosphere injector has been designed within the vessel to deliver the required experimental atmosphere directly onto the material, facilitating more complete reactions.

    ·   Placing the sample flat on the inner tube allows simultaneous gas flow through both the inner and outer tubes. A horizontally positioned sample facilitates thin-film growth and electrode testing, while ensuring more uniform temperature distribution.

    ·   The device also supports functions such as oxide crystal growth and annealing.

    Main Parameters

    · Rated voltage: AC 220V 50/60 Hz, Heating power: 1.3 kW

    · Maximum temperature: 1200℃

    · Continuous Operating temperature: ≤1100℃

    · Recommended heating rate : ≤10℃/min

    ·   Heating zone length: 230 mm, Constant-temperature zone length: 100 mm

    · Heating element: resistance wire (molybdenum‑doped iron‑chromium‑aluminum alloy)

    · Thermocouple: Type K

    Furnace tube &Flange

    ·   High-purity quartz tube Φ25/50mm

    ·   It is equipped with a set of stainless steel quick‑connect sealing flanges, sealed with silicone O‑rings.

    · Vacuum level: 0.5 Pa (using a mechanical pump)

    · It is equipped with a mechanical pressure gauge, with a measurement range of -0.1 to 0.15 MPa.

    Temperature control system

    ·   Fuzzy PID Control and Self-Tuning Regulation

    ·   Intelligent 30-segment programmable control allows customers to customize heating and cooling profiles according to their specific needs.

    ·   Features ultra‑gentle operation and open‑circuit alarm functionality.

    · Temperature control accuracy: ±1℃

    Vacuum System (Optional)

    ·   Model: DRV-10

    · Pumping rate: 10 m³/h

    · Ultimate pressure: 5×10 -1 Pa (no-load, cold state)

    · Oil capacity: 1.1 L

    · Inlet/Outlet Port Diameter: KF25

    (Optional: domestically produced or imported high-vacuum unit)

      

    Size &Weight

    · Overall equipment dimensions: 330mm × 330mm × 1080mm (Length × Width × Height)

    · Equipment net weight: approximately 45 kg

    Warranty period

    ·   One-year warranty, lifetime maintenance.

    · Consumable items such as thermocouples, silicone rings, furnace tubes, and sample crucibles are not included.

    · Damage caused by improper use, as well as damage resulting from the use of corrosive or acidic gases, is not covered under the warranty.

    Precautions

    ·   The internal air pressure must not exceed 0.02 MPa (gauge pressure).

    ·   Due to the high internal pressure of the gas cylinder, a pressure-reducing valve must be installed when introducing gas into the pipeline. To ensure safety, it is recommended to select a pressure-reducing valve with a rated pressure below 0.02 MPa and a measurement range of 0.01–0.1 MPa, which will provide greater accuracy and safety during operation.

    ·   For experiments involving sample heating, it is not recommended to operate the system with both the vacuum valve and the purge valve at the furnace tube flange closed. If it becomes necessary to close these valves during heating, closely monitor the pressure gauge; if the pressure exceeds 0.02 MPa, immediately open the vent valve to prevent potential accidents, such as rupture of the furnace tube or ejection of the flange.

    ·   Customers are advised against using flammable, explosive, or toxic gases. If such gases are unavoidably required for process reasons, please implement all necessary safety and explosion‑proof measures on your own. Our company shall not be held liable for any issues arising from the use of flammable, explosive, or toxic gases.