1750℃ High-Temperature Tube Furnace BTF-1750C

Equipment Model: BTF-1750C Equipment Overview: A tube furnace with high‑temperature silicon‑molybdenum rod heating, capable of reaching 1750°C. The furnace features a double‑wall air‑cooling system, ensuring that the outer shell temperature remains below 60°C even at full operating temperature. Insulation is made from vacuum‑adsorbed alumina fiber, an inorganic material that is free of contaminants, clean, and aesthetically pleasing. Support brackets are installed at both ends of the flange to reduce stress on the heating tube, thereby extending its service life. The technology is well‑proven and reliable, offering uniform temperature distribution and a robust, well‑designed structure. Process Applications: Widely used in experimental settings requiring elevated temperatures, such as vacuum or controlled‑atmosphere sintering and substrate coating. It is also employed in cutting‑edge fields like semiconductors, nanomaterials, carbon fibers, graphene, and other emerging materials and processes.

Keywords:

Close
  • 产品对比
Total X Clear all
  • Product Information
  • Product Video
  • Experimental Case
  • Accessories and Consumables
  • Key Features

    ·   The furnace body features a double-layer air-cooling system; even at the maximum operating temperature, the outer surface temperature remains below 60°C.

    ·   The insulation material is an inorganic alumina fiber product formed by vacuum adsorption, free of contaminants, clean, and aesthetically pleasing.

    ·   Support brackets are installed at both ends of the flange to reduce the load on the furnace tubes and ensure their service life.

    ·   Mature technology, reliable quality, uniform temperature distribution, and a well‑designed structure.

    Main Parameters

    · Voltage: AC 208-240 V, 50/60 Hz , Rated power: 5.2 kW

    · Maximum temperature: 1750℃

    · Continuous Operating temperature: ≤1700℃

    · Recommended heating rate: ≤10°C/min below 1400°C, and from 1400°C to 1650°C.   ≤5℃/min

    ·   Heating zone length: 300 mm, Constant-temperature zone length: 150 mm

    · Heating element: imported silicon-molybdenum rod

    · Thermocouple: Type S thermocouple

    Furnace tube &Flange

    ·   Furnace tube diameter: Alumina tube, 100 mm (outer diameter) × 1300 mm (tube length; diameter customizable)

    ·   It is equipped with a set of stainless steel quick‑connect flanges (available in two types: clamp flanges and hinge flanges) and sealed with silicone O‑rings.

    · It is equipped with a mechanical pressure gauge, with a measurement range of -0.1 to 0.15 MPa.

    · Use a pipe plug to block the thermal radiation emitted from the center of the pipe; this must be done before heating and positioned correctly within the furnace chamber.

    Temperature control system

    ·   Fuzzy PID Control and Self-Tuning Regulation

    ·   Intelligent 30-segment programmable control allows customers to customize heating and cooling profiles according to their specific needs.

    ·   Features ultra‑gentle operation and open‑circuit alarm functionality.

    · Temperature control accuracy: ±1℃

    Vacuum pressure

    ·   The mechanical pump can reach 10. -1 Pa

    ·   The molecular pump can reach 10. -3 Pa

    Size &Weight

    · Device dimensions: 610*440*720mm (excluding the furnace tube and flange)

    · Equipment net weight: approximately 130 kg

    Warranty period

    ·   One-year warranty, lifetime maintenance.

    · Consumable items such as thermocouples, silicone rings, quartz tubes, and sample crucibles are not included.

    · Damage caused by improper user handling, as well as damage resulting from the use of corrosive or acidic gases, is not covered under warranty.

    Precautions

    ·   The internal air pressure must not exceed 0.02 MPa (gauge pressure).

    ·   Due to the high internal pressure of the gas cylinder, a pressure-reducing valve must be installed when introducing gas into the pipeline. To ensure safety, it is recommended to use a pressure-reducing valve with a rated pressure below 0.02 MPa and a measurement range of 0.01–0.1 MPa, which will provide greater accuracy and safety during operation.

    ·   For experiments involving sample heating, it is not recommended to operate the system with both the vacuum valve and the inlet valve at the furnace tube flange closed. If it becomes necessary to close these valves during heating, continuously monitor the pressure gauge; if the pressure exceeds 0.02 MPa, immediately open the vent valve to prevent potential accidents, such as rupture of the furnace tube or ejection of the flange.

    ·   Customers are advised against using flammable, explosive, or toxic gases. If such gases are unavoidably required for process reasons, please implement all necessary safety and explosion‑proof measures on your own. Our company shall not be held liable for any issues arising from the use of flammable, explosive, or toxic gases.

    · The gas flow rate should be less than 200 SCCM (200 mL/min).

    · Due to the manufacturing process of alumina tubes, there is a risk of tube breakage during the sintering process, which cannot be entirely avoided. Please be advised.