undefined
undefined
+
  • undefined
  • undefined

1200℃ Miniature Dual-Zone Tube Furnace BTF-1200C-II-S

Equipment Model: BTF-1200C-II-S Equipment Overview: This mini‑size, dual‑zone tube furnace features a compact design and exceptionally rapid heating. It supports both vacuum evacuation and inert gas purging, and its furnace tubes are easy to install and remove. Operation is straightforward: users can directly transfer the sealed chamber out of the furnace body to accelerate cooling. The transparent quartz tube allows for real‑time observation of the sample’s sintering process. The workpiece passes horizontally through the furnace chamber, which is equipped with imported resistance wire, ensuring a uniform temperature profile; the temperature difference between the interior and exterior can be maintained within approximately ±3°C. The BTF-1200C-II-S mini dual‑zone tube furnace offers outstanding cost‑effectiveness.

Keywords:

Close
  • 产品对比
Total X Clear all
  • Product Information
  • Product Video
  • Experimental Case
  • Accessories and Consumables
  • Key Features

    ·   1200℃ open‑type mini vacuum tube furnace with a compact body (net weight only 18 kg)

    ·   It heats up extremely quickly and can both evacuate a vacuum and purge with protective gas.

    ·   Its design facilitates easy disassembly and assembly of the furnace tubes, ensuring straightforward operation.

    ·   The user can directly remove the sealed chamber from the furnace body, accelerating the cooling process.

    ·   The transparent quartz tube chamber allows for direct observation of the sample’s sintering state.

    ·   The furnace tube carries the workpiece across the furnace chamber, which is equipped with imported resistance heating wires; the temperature field is uniform, and the temperature difference between the interior and exterior can be maintained within approximately ±3°C.

    ·   The mini dual-zone tube furnace is a highly cost-effective tube furnace.

    Main Parameters

    · Voltage: AC 220V 50/60Hz , Rated power: 3 kW

    · Maximum temperature: 1200℃

    · Continuous Operating temperature: ≤1100℃

    · Recommended heating rate: ≤10°C/min

    ·   Heating zone length: 100+100 mm

    · Heating element: resistance wire

    · Thermocouple: Type K thermocouple

    · Temperature control accuracy: ±1℃

    Flange

    ·   Stainless steel sealed flanges (including precision needle valves, pointer-type vacuum pressure gauges, and hose‑type swivel fittings) are sealed with silicone O‑rings.

    Temperature control system

    ·   Fuzzy PID Control and Self-Tuning Regulation

    ·   Intelligent 30-segment programmable control

    Size &Weight

    · Device dimensions: 570x380x500mm

    · Equipment net weight: approximately 40 kg

    Low-vacuum unit ( VAU-02)

    ·   Model: VAU-02 (includes one internally mounted mechanical pump, one resistance vacuum gauge, and accompanying components such as a bellows, manual butterfly valve, clamps, and other connecting parts)

    ·   Relative air humidity: ≤85%

    · Operating voltage: 220V ±10%, 50–60 Hz

    · Power: 1 kW

    ·   Pumping rate: 10 m³/h

    ·   Ultimate vacuum: 4 × 10 -2 Pa

    ·   Experimental vacuum level: 1.0 × 10 -1 Pa

    · Oil capacity: 1.1 L

    ·   Inlet diameter: KF25

    ·   Exhaust port diameter: KF25

    ·   Rotational speed: 1450 rpm

    ·   Noise: 50 dB

    ·   External dimensions: 600 x 600 x 600 mm

    Vacuum gauge parameters

    ·   Regulatory compliance : ZJ-52T Resistance Gauge

    ·   Measurement range: 10 5 Approximately 10 -1 Pa

    ·   Measurement channels: 1 channel

    ·   Control range: 5 x 10 3 ~5 x 10 -1 Pa

    ·   Control method: Relay contact output, with a load capacity of AC 220 V/3 A (or DC 28 V/3 A) for resistive loads.

    ·   Power supply: 90–260 V / 50 Hz or 220 V ± 10% 50 Hz

    ·   Power consumption: 20W

    Warranty period

    ·   One-year warranty, lifetime maintenance.

    · Consumable items such as thermocouples, silicone rings, quartz tubes, and sample crucibles are not included.

    · Damage caused by the use of corrosive gases and acidic gases is not covered under warranty.

    Precautions

    ·   The gas pressure inside the quartz tube must not exceed 0.02 MPa (gauge pressure).

    ·   For experiments involving sample heating, it is not recommended to operate the system with both the vacuum valve and the inlet valve at the furnace tube flange closed. If it is necessary to close these valves during heating, continuously monitor the pressure gauge; if the pressure exceeds 0.02 MPa, immediately open the vent valve to prevent accidents such as furnace tube rupture or flange ejection.

    ·   If, due to process requirements, flammable, explosive, or toxic gases must be used, you are responsible for implementing all necessary safety and explosion‑proof measures. Our company shall not be liable for any issues arising from improper operation during the use of such gases.

    ·   As the furnace is used over time, minor cracks may develop; this is normal, and the cracks can be repaired with an alumina coating.