1200℃ Three-Zone Tube Furnace BTF-1200C-III-D80

Equipment Model: BTF-1200C-III-D80 Equipment Overview: The BTF-1200C-III-D80 is a high-performance, open‑type tube furnace with three temperature zones. It can operate at a maximum temperature of 1200°C, with typical operating temperatures up to 1100°C. The furnace features an alumina fiber furnace body formed by vacuum‑assisted molding, offering environmental friendliness, energy efficiency, cleanliness, excellent thermal insulation, and a long service life. The internal temperature field is highly uniform, and when paired with K‑type thermocouples and premium resistance wires, it ensures stable and reliable heating. A key feature of this equipment is its custom‑designed lateral flange assembly, which incorporates three inlet ports at the gas‑supply end and a unique shaped gas‑delivery conduit. This design enables precise gas delivery to two distinct temperature zones. Standard configuration includes two sizes of tapered T‑shaped quartz tubes, while the flanges utilize quick‑release clamp seals for easy installation and removal. Additionally, the longitudinal multi‑port interface provides exceptional flexibility for future expansion. The electrical control system employs an intelligent 30‑step programmable controller based on a fuzzy PID algorithm, delivering high temperature‑control accuracy (±1°C) and incorporating safety alarms for over‑temperature and thermocouple breakage. Operation is straightforward, with precise and reliable control.

Keywords:

Close
  • 产品对比
Total X Clear all
  • Product Information
  • Product Video
  • Experimental Case
  • Accessories and Consumables
  • Key Features

    ·   Customized Heating Furnace Body

    The heating furnace employs vacuum‑formed alumina fiber, an inorganic material that is environmentally friendly and energy‑efficient, free of contaminants, clean, and aesthetically pleasing. Temperature measurement is achieved with K‑type thermocouples, while high‑quality resistance wire serves as the heating element, ensuring a uniform internal temperature field and a long service life.

    ·   Customized Horizontal Flange Assembly

    The flange structure at the lateral air inlet is custom‑designed to meet customer requirements. The inlet features three air inlets, and the inlet blind plate is equipped with dual air‑guiding ducts that deliver airflow. These ducts have a non‑standard geometry, channeling air separately into the first temperature‑controlled zone and the second temperature‑controlled zone. The equipment includes two quartz tubes of different specifications (other sizes are also available as options). The flanges employ a clamp‑type sealing mechanism, enabling quick and easy installation and removal. Additionally, the flanges incorporate a longitudinal multi‑port design, with auxiliary ports offering high scalability.

    ·   Electrical Control System

    The temperature controller employs fuzzy PID control and auto-tuning, featuring intelligent 30-segment programmable control, with over-temperature and thermocouple‑open‑circuit alarm functions; its temperature control accuracy reaches ±1°C.

    Main Parameters

    · Rated voltage: AC 220V 50/60Hz , Rated power: 8KW

    · Maximum temperature: 1200℃

    · Continuous Operating temperature: ≤1100℃

    · Recommended heating rate: ≤10°C/min

    ·   Heating zone length: 300+300+300 mm

    · Heating element: resistance wire

    · Thermocouple: Type K thermocouple

    Temperature control system

    ·   Fuzzy PID Control and Self-Tuning Regulation

    ·   Intelligent 30-segment programmable control allows customers to customize heating and cooling profiles according to their specific needs.

    ·   Features ultra‑gentle operation and open‑circuit alarm functionality.

    · Temperature control accuracy: ±1℃

    Size &Weight

    · Device dimensions: 1700x680x580mm

    · Equipment net weight: approximately 125 kg

    Warranty period

    ·   One-year warranty, lifetime maintenance.

    · Consumable items such as thermocouples, silicone rings, quartz tubes, and sample crucibles are not included.

    · Damage caused by the use of corrosive gases and acidic gases is not covered under warranty.

    Precautions

    ·   The gas pressure inside the quartz tube must not exceed 0.02 MPa (gauge pressure).

    ·   For experiments involving sample heating, it is not recommended to operate the system with both the vacuum valve and the inlet valve at the furnace tube flange closed. If it becomes necessary to close these valves during heating, continuously monitor the pressure gauge; if the pressure exceeds 0.02 MPa, immediately open the vent valve to prevent potential accidents, such as rupture of the furnace tube or ejection of the flange.

    ·   If, due to process requirements, flammable, explosive, or toxic gases must be used, you are responsible for implementing all necessary safety and explosion‑proof measures. Our company shall not be liable for any issues arising from improper operation during the use of such gases.

    ·   As the furnace is used over time, minor cracks may develop; this is normal, and the cracks can be repaired with an alumina coating.