Equipment Model: BOF-800C-8D-100 Equipment Overview: This is a high‑vacuum integrated tube furnace. The system comprises three main components: eight independent heating zones, a high‑vacuum assembly, and an intelligent control unit. Each of the eight independently operable tube furnaces features an open‑type design, allowing convenient observation of the sintering process and rapid cooling. The vacuum and heating parameters for each zone can be controlled separately. A high‑vacuum molecular pump is employed to evacuate the main pipeline and is connected to the eight individual heating chambers; pneumatic slide valves enable independent vacuum control for each chamber. The system utilizes intelligent PID fuzzy control with 30 programmable segments and includes over‑temperature and thermocouple‑break alarm functions.

Keywords:

Close
  • 产品对比
Total X Clear all
  • Product Information
  • Product Video
  • Experimental Case
  • Accessories and Consumables
  • Key Features

    · Eight zones with independent vacuum and heating control, ensuring uniform temperature field.

    · The ultimate vacuum level within a single chamber can exceed 1×10⁻⁶ Pa. -4 Pa

    · Equipped with two high-vacuum systems, the material can be easily loaded and unloaded.

    · A slanted conical adsorption cold trap with no fixed components, offering convenient use and cleaning.

    · The butterfly nut secures the flange cover, eliminating the need for tools throughout the entire process.

    · Supports customization across various process specifications, including 4-, 6-, 8-, 16-, and 32‑cavity configurations.

    Main Parameters

    · Voltage: AC 380V, 50/60 Hz; equipment power: 26 kW; total heating power: 24 kW.

    · Continuous operating temperature: ≤ 800℃

    · Heating and cooling rate: ≤10°C/min

    · Temperature control duration: ≥200 hours

    · Heating zone dimensions: Φ120 x 400 mm

    · Vacuum specification: The remote vacuum limit is close to 10. -4 Pa

    · Heating element: resistance wire

    · Temperature sensing element: Type K thermocouple

    Temperature control system

    ·   Fuzzy PID Control and Self-Tuning Regulation

    · AI-enabled 30-segment programmable control

    ·   Features ultra‑gentle operation and open‑circuit alarm functionality.

    · Temperature control accuracy: ±1℃

    Equipment dimensions &Weight

    · Equipment main body dimensions: 2890 x 1250 x 2045 mm (Length × Width × Height)

    · Equipment weight: approximately 1,100 kg

    Warranty period

    ·   One-year warranty, lifetime maintenance.

    · Consumable items such as thermocouples, silicone rings, quartz tubes, and sample crucibles are not included.

    · Issues arising from improper use or the use of corrosive gases, acidic gases, and similar substances are not covered under the warranty.

    Precautions

    ·   The gas pressure inside the quartz tube must not exceed 0.02 MPa (gauge pressure).

    · Due to the high internal pressure of the gas cylinder, a pressure-reducing valve must be installed when introducing gas into the quartz tube. To ensure safety, the pressure after reduction should be maintained at 0.2–0.4 MPa, and the reduced-pressure gas must pass through a flow meter to regulate the flow before entering the furnace tube.

    ·   For experiments involving sample heating, it is not recommended to close the vacuum and inlet valves at the flange end of the furnace tube. If it is necessary to close these valves during sample heating, continuously monitor the mechanical pressure gauge; if the gauge reading exceeds 0.02 MPa, immediately open the vent valve to prevent accidents such as furnace tube rupture or flange ejection.

    ·   If, due to process requirements, flammable, explosive, or toxic gases must be used, you are responsible for implementing all necessary safety and explosion‑proof measures. Our company shall not be liable for any issues arising from improper operation during the use of such gases.

    · As the furnace is used over time, minor cracks may develop in the furnace chamber; this is normal, and the cracks can be repaired with a high-purity alumina repair coating.